Inactivation - Descriptions, Relationships, and Concepts
How do I Inactivate a Description?
Steps | Reference |
---|---|
Load the concept in the edit panel whose description you want to inactivate. Note the | |
Press | |
A
| |
Reason "Not semantically equivalent" requires completion of the REFERS TO concept association reference set entry. The target concept field has the same type-ahead search support as relationship target fields in the edit panel - start typing a word stem and the corresponding concepts will be presented for selection in a drop-down list. The field can also be populated by cut and paste (typically used when the target concept SCTID is available for cut and paste). | |
Once the association reference set target is set, the | |
For inactivation reasons other than "Not Semantically Equivalent", there is no need to specify any additional information, so the Association Type field setting is not presented. Simply press the | |
After pressing | |
To see the inactivated description (for instance to confirm/review the changes), press the | |
To view the inactivation details for an inactive description, press the |
How do I Inactivate a Relationship?
Steps | Reference |
---|---|
On a relationship the button will inactivate the relationship. |
How do I inactivate a Concept?
Steps | Reference |
---|---|
On a description the button will trigger the Select Reason For Inactivating Description dialog. The dialog will also display three additional tabs: Children, Descendants, and All Incoming For informational purposes. All three fields: inactivation reason, association type, and concept are required. Once filled in select the Continue With Concept Inactivation button | |
The Inactivation pane will appear with three tabs Children Affected, Attributes Affected, and Historical Associations Affected. Each of these tabs will present the affected Children, Attributes, and Historical Associations with a proposed new modelling. All concepts have to be Accepted before continuing with Inactivation. To accept a Concept as proposed select the Approve to approve it. Note: if a concept is approved in error selecting the Unapprove button will revert the approval. To accept a batch of concepts simply select the Accept All button. Note: concepts on all tabs must be accepted in order to continue.
| |
To view a concept selecting the Edit button will load the concept as the modelling is proposed. | |
Once all Concepts have been approved select the Complete Inactivation button to finalize the inactivation. | |
The UI will indicate that it is “Saving modified components and historical associations... “ Once complete the ui will refresh and load the concept in its current inactive state. |
Copyright © 2025, SNOMED International